Attractions

Calibration is required in the process of controlling our equipment if we are to ensure the traceability of measurements.

With the help of etalon weights we verify the accuracy of our indication, eccentricity and repetability.
Lenght and angle
GAUGE BLOCKS
Gauge blocks calibration up to 1000 mm in accordance with international standard SIST EN ISO 3650:
- By measuring medium length.
- By measuring length variation in four points.
Calibration is performed in our laboratory, in a controlled atmosphere.
The reference temperature is 20 °C.
We clean the measuring device and packaging and perform smaller repairs, and after calibration, we protect the blocks from corrosion.
![]() | ![]() |
DIAL GAUGES AND ELECTRONIC PROBES
Calibration of dial gauges is performed in accordance with standard VDI/VDE/DGQ 2618 on a linear measuring machine or with reference gauge blocks:
- By measuring at 10 points equally distributed across the measuring range.
- By measuring 5 repetitions of measuring device indication.
- By measuring at 10 points within a selected range.
Calibration is performed in the laboratory and on-site.
Calibration of electronic probes is performed according to the method of comparison on a linear measuring machine or with reference gauge blocks:
- measuring at 5 points equally distributed across the measuring range.
- By measuring 5 repetitions of measuring device indication.
Calibration is performed in the laboratory and on-site.
![]() | ![]() |
VERNIER CALLIPERS
Calibration of Vernier callipers is performed in accordance with standard VDI/VDE/DGQ 2618 using the method of comparison with reference gauge blocks and ring gauges:
- By measuring external jaws with at least 4 gauge blocks.
- By measuring internal jaws with 2 ring gauges.
- By measuring depth probe at 1 point.
- By measuring step probe at 1 point.
We clean the measuring device and packaging and perform smaller repairs.
![]() | ![]() |
SCREW MEASURES – MICROMETERS
We perform calibration of all micrometers.
The calibration of micrometers is performed in accordance with standard VDI/VDE/DGQ 2618 using the method of comparison with reference gauge blocks:
- By measuring the flatness of surface with optic gauge.
- By measuring parallelism of surfaces with gauge block.
- By measuring zero point with gauge block.
- By measuring indication accuracy at 10 points over the entire range.
We perform calibration of setting measurements and extensions.
At calibration, we also set the zero point indication and, if required, polish the measuring surfaces.
We clean the measuring device and packaging and perform smaller repairs.
![]() | ![]() |
PLAIN RING AND PLUG GAUGES
We perform calibration up to 1000 mm in diameter.
Calibration of plain ring and plug gauges is performed in accordance with guideline EURAMET/cg-06:
- By measuring medium diameter at 5 points.
- By measuring variation in 2 or 4 additional points of nominal diameter.
- By measuring variation in 2 additional points, shifted for 60° and 120°.
Calibration is performed in our laboratory, in a controlled atmosphere.
The reference temperature is 20 °C.
We clean the measuring device and protect it from corrosion after calibration.
![]() | ![]() |
THREAD RING AND PLUG GAUGES
We perform calibration up to 300 mm in diameter for following threads:
- Metric threads (ISO) up to M300 with thread pitch up to 6 mm (?=60°)
- UNC threads up to R18 with thread pitch up to 3.175 mm (? =55°)
- Trapezoidal threads up to Tr36 with thread pitch up to 6 mm (? =30°)
- Buttress threads up to S36 with thread pitch up to 6 mm (? =30°)
Calibration of thread ring and plug gauges is performed on a linear measuring machine by method of comparison with the help of wires and T-probes with balls:
- By measuring medium diameter at 3 thread points.
- By measuring variation in 2 or 4 additional thread points.
Calibration is performed in our laboratory, in a controlled atmosphere.
The reference temperature is 20 °C.
We clean the measuring device and protect it from corrosion after calibration.
![]() | ![]() |
THICKNESS GAUGES
Calibration of thickness gauges is performed on a linear measuring machine:
- By measuring medium length.
- By measuring length variation in 4 points.
We clean the measuring device and protect it from corrosion after calibration.
![]() | ![]() |
GAP GAUGES
Calibration of gap gauges is performed on a linear measuring machine:
- By measuring medium length.
- By measuring the length in four points.
We clean the measuring device and protect it from corrosion after calibration.
![]() | ![]() |
TAPE MEASURES AND RIGID RULERS
Calibration of tape measures and rigid rulers is performed on a length measuring track by comparison of indication of the measuring device and etalon:
- By measuring at 5 points over the entire range.
- By measuring at additional point on client’s request.
![]() | |
PROTRACTORS
Calibration of protractors is performed by method of comparison with etalon protractor:
- By measuring angle at 5 points over the entire measuring range.
- By measuring angle at additional points on client’s request.
- By measuring reproducibility of the measuring device’s reading.
We clean the measuring device and perform smaller repairs.
![]() | ![]() |
SQUARE GAUGES
Calibration of angles is performed by measuring on a measuring machine:
- By measuring parallelism of jaws.
- By measuring flatness of jaw surfaces.
- By measuring accuracy of the angle.
We clean the measuring device and perform smaller repairs.
![]() | ![]() |
STEP GAUGES
Calibration of step gauges are carried out by measuring on measuring machine:
- by measuring the mean value,
- By measuring of the surface flatness.
We clean the measuring device and perform smaller repairs.
![]() | |
CONSTRUCTION SIEVES
Calibration of the construction sieves are implemented according to SIST ISO 3310-1:
- by measuring the spacing between the wires,
- by measuring the diameter of the wire.
We clean the measuring device and perform smaller repairs.
![]() | |
SPECIAL MEASURES
Calibration of measuring devices is performed on high capacity machines:
- Single coordinate lineal machine.
- Single coordinate measuring track.
- Three coordinate measuring machine.
- Optical measuring machine
We clean the measuring device and perform smaller repairs.
![]() | ![]() |
MEASURING WHEELS
Calibration is carried out on our own developed etalon:
- measuring in at least three measuring points.
We clean the measuring device and perform smaller repairs.
![]() | ![]() |
SERVICE
- We perform service of measuring devices of all types.
- We provide spare parts for most manufacturers of measuring devices.
WHY PERFORM CALIBRATION
- Changes in temperature, humidity, air pressure and other adverse factors influence weighing accuracy, as well as operator’s work.
- Constant use represents wear of measuring devices and therefore change in value.
- Accuracy of measuring devices is not stable time-wise.
- Regular calibration ensures accurate and precise operation of measuring devices.
- At calibration, cleaning and setting of measuring devices is performed.
Certificate, which you are provided with after each calibration, ensure measuring traceability of measuring devices with establishment and maintenance of quality systems (ISO certification), laboratory accreditation and is in accordance with requirements GMP, GLP and GCP.
CALIBRATION PERIOD
Calibration period is set in accordance with standards or recommendations for ensuring quality of measuring equipment SIST ISO 10012, ILAC-G24 / OIML D10.
DETAILD SCOPE OF ACCREDITATION
![]() | Annex to the Accreditation Certificate | LK-008 |
| Issued on | 15. junij 2011 | |
| Replaces Annex dated | 1. april 2011 | |
| Information on current accreditation status is available at: | www.sa.gov.si |
| In laboratory |
| Measured quantity | Range | Best measuring capability BMC (k=2)* | Notes |
| 4 |
| DIMENSIONAL QUANTITIES |
| 4.1 |
| Length |
| 4.1.2 |
| Length measuring devices |
| Guage block | 0,5 mm to 10 mm nad 10 mm to 125 mm nad 125 mm to 1000 mm | 70 nm 60 nm + 1· 10-6·L 100 nm + 1,6·10-6·L | By comparison | |
| Step gauges | 0 mm to 1000 mm | 1,25 μm + 5,5·10-5·L | Measuring area: < 100 mm x 100 mm | |
| Dial gauges | 0 mm to 100 mm | 0,4 μm + 2·10-5·L | In laboratory and on-site. On-site calibration only with load | |
| Tire depth gauges | 0 mm to 100 mm | 0,03 mm | In laboratory and on-site | |
| Electronic probes | 0 mm to 100 mm | 0,4 μm + 2·10-5·L | In laboratory and on-site Calibration on-site without evaluation of hysteresis | |
| Thickness gauges | 0 mm to 1000 mm | 0,2 μm + 6·10-6·L | Measuring area: < 100 mm x 100 mm | |
| Gap gauges | 0 mm to 1000 mm | 1,25 μm + 5,5·10-6·L | Measuring area: < 100 mm x 100 mm |
| 4.1.3 |
| Line scales, distances |
| Rulers/td> | 0 mm to 4000 mm | 50 μm + 3·10-6·L | ||
| Tape measures | 0 mm to 200 m | 50 μm + 3·10-6·L |
| 4.1.4 |
| Length measuring devices |
| Two point micrometers (external and internal) | 0 mm to 2000 mm | 1,5 μm + 5·10-6·L | ||
| Vernier calliper gauges | 0 mm to 2000 mm | 7,5 μm + 8·10-6·L | ||
| Laser distance meters | 0 mm to 4000 mm | 0,1 mm | ||
| Ultrasonic thickness meters | 0 mm to 50 mm | 0,15 mm + 6·10-3·L (L v mm) | ||
| Magnetic thickness meters | 0 mm to 1500 μm | 7 μm | ||
| Distance measuring wheels | 0 m to 1000 m | 10 mm + 0,15·L | ||
| Test sieves | to 400 mm | 3,8 μm + 5·10-6·L | ISO 3310 |
| 4.1.5 |
| Diameter |
| Notranji premer |
| Three point micrometers | 0 mm to 300 mm | 1,5 μm + 5·10-6·L | ||
| Ring gauges | 2 mm to 800 mm | 1,25 μm + 5,5·10-6·L |
| External diameter |
| Plug gauges | 0 mm to 300 mm | 0,2 μm + 6·10-6·L |
| 4.1.8 |
| Thread quantities |
| Screw ring gauges |
| Medium diameter | 3 mm to 300 mm | α=30°; 5 μm + 5·10-5·L α=55°; 3 μm + 7,5·10-6·L α=60°; 3,5 μm + 6·10-6·L | Rate in the range 0,35 mm to 6mm α= thread angle (according to EURAMET/cg.10/v.01, method 1a) |
| Screw plug gauges |
| Medium diameter | 3 mm to 300 mm | α=30°; 5 μm + 5·10-5·L α=55°; 3 μm + 7,5·10-6·L α=60°; 3,5 μm + 6·10-6·L | Rate in the range 0,35 mm to 6mm α= thread angle (according to EURAMET/cg.10/v.01, method 1a) |
| 4.2 |
| Angle |
| Protractor | 0° to 360° | 15˝ | ||
| level meters | -5 mm to 5 mm -0,8° to 0,8° | 25 µm/m 5˝ |
WHY CHOOSE US
- Slovenian accreditation constantly audit our technical staff and equipment.
- Results of inter-laboratory comparisons show good work of the laboratory.
- We provide quick reaction time from order to service implementation.
- We strive to interfere with the work process as less as possible when providing service.
- Constant training of our staff enables us quality service.
- All of our measuring equipment has secured measuring traceability on national or international etalon.
- We inform you regularly on the date of next calibration.
- MeOL: electronic monitoring of measuring devices over the Internet.
- Trust of auditors and inspectors in our results.
SALE
We provide the appropriate measure of length from different manufacturers.
|
![]() |
|
|























.jpg)